Quantcast
Channel: GE Intelligent Platforms e-Forum
↧

Item had unknown error

in a Cimplicity project, I have two devices, both connected to PLC using an OPC server. In the logging of Cimplicity, I see a few times a day some errors: 23/12/2015 0:54:56 Failure 5548 OPC_0...

View Article


SLider Control

Trying to use the Microsoft OLE slider Control It goes from top to bottom 0 - 25 I need it to go bottom to top 0 - 25 Also need a way to refresh its location when the tag it changes is changed May not...

View Article


Virtual PT = to Modbus PT not the same

I have a Modbus point that has a value in Cimplicity Point Control Panel as 10.50. If I set up a virtual point and make it calculation, equation and put the Modbus point as the expression, it has the...

View Article

Backup

Does the backup application backup recipe databases?

View Article

RDP Session - Keyboard Locks Up

Hi. We are having a major issue with our iFix 5.8 deployment. We have 2 virtual machines both running Windows Server 2012: SCADA node and terminal services view node. There is a single client running...

View Article


Help on writing from iFIX directly to IGS Server

Good Morning, I have an iFIX application in the beer industry (iFIX version: 5.1) and an accessing PLCs Simens S7-300 trough Ethernet TCP/IP Protocol and IGS Server V7.59. OS: Windows XP Professional...

View Article

Using STALE DATA

Does anyone know the syntax for testing a tag to see if it is stale data or not in VB ? I know how to set the Port as STALE DATA but do not know how to check a signal. I remember seeing it somewhere.

View Article

Alarm ODBC - experiences and suggestions

Our costumer needs to analyze and query alarm and events history. So I am planning to create some SQL database, and query table in some application, maybe C#. The queries will be on time, tag name,...

View Article


IDTPOP output and IDX files

I was just looking at an IDTPOP outfile file and was wondering if there is an explanation somewhere of the fields. Some of them make sense, but others dont. or at least what I would expect. i.E...

View Article


Local Change management Requirement

Do I need Visual SourceSafe installed in order to use the Local Change Management for Proficy Machine Edition? I can not get it to work. When I enable the Local Change Management and continue to log...

View Article

How to assign different ALARM CLASS to Objects Date Items of same Class?

In my application I have created one class for HT Pump. There are 10 such types of pumps. As per customer requirement he wants individual Alarms Screen for each Pump. For that I have created P1 to P10...

View Article

Licensing: *.plic vs *.ilicense files

Dear community, I've downloaded several key license files. Some of them have *.plic file extension, while others have *.ilicense. Could someone explain the difference? Thank you.

View Article

color animation in a group issue ?

I have group that has two rectangles in it. The object have a default fill color. In my animation i change the the fill color based on a signal. However, the animation does not work unless i change...

View Article


Webspace 4.8.2 client on MAC OS 10.11.2 incompatible

When installing the package Proficy Webspace Client 4.8.2 for Macintosh, the .dmg presents a warning regarding incompatability with the present OS (which is 10.11.2), AKA El Capitan. Is there a newer...

View Article

IC220SDL953 Versa Safe

We had a versa point I/O system come on a new machine we bought , the Safety portion of the I/O keeps faulting out with a "PWR cycle Requ". Does anyone have experience with this? We did not program it...

View Article



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>