iFix tolkit adapter requirement
Hi all in the iFix integration toolkit adapter i found this: iFIX Toolkit Adapter Requirements ( Microsoft® Visual Studio 2010® SP1 recommended iFIX 5.5 installed and configured, which installs .NET...
View ArticleProficy View Runtime E-Mail alarms
I have set up Our HMI (Proficy Machine edition 7 Sim 21 View Runtime Sim 1 build 5517). To Email when a Variable go low or high in our Root alarm Group. It has been working for many years. Just before...
View ArticleLearning Historian
I am totally new to Historian. Can someone point me in the right direction to learning this as quickly as possible? JP
View ArticleProblem of convert datetime with crystal report and iHistorian ole db provider
Hello. I use Crystal Report 11 and Historian 5.5. I have to create a report on the ihRawData table with Crystal Report for the users. I filter the data on the TimeStamp field. But Crystal Report...
View Articleold LM90 question
LM90 V7.0x talking serially to a 9070 from a DOS pc (the good old days, I also have an 8-track playing in the background) - everything works ok except when I go to view the ladder in monitor or...
View ArticleiFix 5.5 IGS 7.58 Communication Issues
I am using IGS 7.58/iFix 5.5, 10 different PLC's all allen bradley. I am having trouble with one of the channels using an CompactLogix 5300. I keep getting connection timeouts " 'CHANNEL10.CP10' with...
View ArticleIT broke our trend displays
I have a customer with running iFix v5.1 SCADA/View with the standard historian on a single Win7 x32 PC. It had been running fine for over a year. IT recently came through and applied a bunch of...
View ArticleOption Button Dialog Box Selection
Hello, looking for some cimplicity scripting help on option buttons for dialog boxes. Help file below shows an example of three selections. How do I write what was selected to a PLC Point Variable?...
View ArticleiFix 5.8 driver
Hi all when I install iFix 5.8, should I then install any driver (like SIX) or it is included in iFix? thx
View ArticleRegister custom dot net compoents in Windows 2008 R2
Hi All, When trying to register a custom dot net component in CimEdit, through the 'dot net component browser' dialog box I get a non descript run time error, before CimEdit terminates. This only...
View ArticleFullscreen pictures with webspace
In a new system I'm setting up I use iFIX 5.8 and latest webspace in same scada. When using browser(latest Firefox) a few percent of the pictures are truncated and isn't possible to view at all=no...
View ArticleiFIX system not started!
I have installed the iFIX and FIX Desktop V3.5 from the CD. After the installation I double clicked on the iFIX workspace but nothing happens When double click the View under Fix Desktop I am getting...
View ArticleBack to Previous Picture With Multiple Displays
Hello, I'm trying to set up a button to return to the previous opened picture. I followed the instructions of the KB1513, which recommends the use of Me.FullyQualifiedName to get the name of the...
View ArticleConverting Dynamo Sets
Dear community, Did anybody have success downgrading graphical dynamos (Dynamo Sets)? For example a dynamo set was created on version 5.8 and needs to be running on 5.0. When I try opening such dynamo...
View ArticleiFix 5.8 - Alarm logging to SQL Server
I'm struggling to get iFix 5.8 Alarm ODBC Service to write to SQL Server database. Are there any walk-though examples of how to set this up? The e-books were not helpful at all. If no examples exist,...
View ArticleProjekt from iFix 5.5 to 5.8
Hi all can someone tell me witch folder should I copy, to open a project (witch done with iFix 5.5) with iFix 5.8? thx in advance
View ArticleiFix 5.8 Terminal Service
Hi I have problem with security in iFix 5.8 Terminal Service mode. I set user name and password in SCU, but I can not logon to iFIx. I have gotten alert " incorrect password or login". I am sure that...
View ArticleHow to limit OPC clients access to points using Cimplicity OPC Server
I would like to know if there is a way to block the access of points, from OPC Clients with Cimplicity OPC Server. I read the Help file but could not understand if the "select attibutes" from the OPC...
View ArticleMdobus/TCP performance?
Hi All. Our RX3i communicates with 4 devices (robots) using Modbus/TCP via ETM001. I'm trying to maximize comm speed. Current CPU sweep is around 3.7ms. No limitations on the backplane comm window. I...
View Article