Configuration Of Material Master

Hi, I am testing Proficy PA - ERP (SAP) integration. Using Proficy PA, Proficy Workflow, Proficy Open enterprise Come across some B2MML mapping and schemas in Plant Apps, Workflow and Open Enterprise...

View Article


Can't load firmware on CMM321

I have been attempting to reload firmware version 2.20 into two CMM321's without success. These are -EF and -DE versions with AAUI ports, which I use. These modules both assume the software load state...

View Article


(C#) Copying Alarm Events/Messages from Viewer into Textbox?

Good morning. I'm currently working on a .NET (C#) application with Cimplicity's Alarm Viewer ocx placed within a windows form. I'm trying to write code that will allow me to copy the alarm...

View Article

Unable to save updated RTIP picture

I have one picture that after I modify it and try to save it, it gets saved with the following suffixes, .err and .java. When I try to re-open the picture it displays the origal screen without the...

View Article

A way to lock object size?

Is there a way to "lock" an object's size so that it cannot be scaled? I am trying to build a group consisting of a few objects one of which is a button panel. This group can be re-sized for different...

View Article


Server migration

I am just planning a migration from our exiting historian win2003 server to a new win 2008r2 64 bit server on VMware. I have 7 ifix collectors on remote servers and approx 50 clients that access...

View Article

CIMPLICITY 8.0 redundancy problem

I have Cimplicity 8.0 HMI redundant system running on Windows server 2008 OS and facing problem with server redundancy. Problems: 1) System Alarm Message " $RTR_link_down - Node Server1 detects link...

View Article

D200 to Cimplicity 6.1 Odd? behavior on Failover

We have a redundant set up of D200's that feed data to Powerlink/Cimplicity. Recently we had to do a minor configuration update to the Primary/Secondary D200, so we have to initiate a failover to keep...

View Article


Historian Data in Client Workstations

Hello everyone, I am working on iFix version 5.1 facing difficulty to show historian trends and reports from client stations. I have configured the Proficy historian on server and is working fine. Now...

View Article


Xtal Reports 8.5 - Trends Missing

I have iFix 3.5 with local (classic) historical data collected at a frequency of 1s for 15 tags. I am using Crystal Reports 8.5 to plot these tags (on separate subreport charts) and subsequently...

View Article

Problem with new devices on the Redundant Server

I have Cimplicity 8.1 SIM 12 HMI redundant system running on Windows server 2008 RS2 OS. Whenever (start(dynamic mode) or stop) i'll add new device in project on primary server, the secondary server...

View Article

Trouble getting data from AI / DI tags

I have a Logix5000 program loaded in an emulator and I'm using the OPC driver. The topic is properly setup in RSLinx. My problem is that the only data that is coming through is either a AR or DR. None...

View Article

Server Client Time Synchronization

Any one know how to Sync the time between server and clients with Cimplicity? The clients do not have an internet connection so internet time is not an option. Tried enabling W32 time service on the...

View Article


DATA_INIT_COMM Issue!!

Dear All, I need an urgent help on following issue. I'm using COMM_REQ command to read data from a remote PLC. I've defined a DATA_INIT_COMM command before the COMM_REQ command and requested 23 bits...

View Article

Seemingly simple VBA animation issues.

I have an object that I what to move from its original location in increments until it reaches a certain horizontal or vertical value and then return to the original location. The script I have works...

View Article


If statement always resolves true when database tags value is unknown.

I developed a script on site and have been working on it in a VMware session with no PLCs and I noticed that one of the IF statements I’m working on always runs. I had been using hardcoded values to...

View Article

iFIX with office 2013

Hi all, Did any of you test office 2013 (Alarm ODBC) and access reporting with iFIX 5.5.

View Article


How to Access User Roles in Cimplicity 8.2 (Advance Viewer)

Hi, How can we access the HMI Screen operator previlege on to the Cimplicity screen and animate the objects. I dont have a project for my screens. Thanks Adithya.

View Article

Comm req hsc 9030

I have a 9030 CPU 350. I am using a COMM_REQ and BLK_MOV to reset the HSC to zero. My question is when I put 4 in the SYSI of the COMM_REQ or 0004 when I have the HSC in the main rack everything works...

View Article

Reload Data after re-configuring variable sampling type

Do you know if I can reload data into a variable after changing its Sampling Type. My example is: variable originally configured with "Last Good Value". I changed it to "Maximum". If I reload the data...

View Article