Cimplicity Window
Hi Gurus.. Does anyone knows if your cimplicity window always start in an offset opposition? For my project, it always launch 2inch by 2inch from the top left corner of the screen. Is it possible to...
View ArticleHow to add 2 class attributes?
Hi rephrasing the title of my previous post...:confused: How can i How to add 2 class attributes, and assign the result to a third attribute (in the same class) The result will be the address of one...
View Articleamrp.exe error message
Hi, Does anyone knows if this is related to some missing hotfix? Thanks.
View ArticleHistorian Table
I want to collect the data every 1 minute interval as like below. Data are polled at every second by collector. TimeStamp TAG1 TAG2 TAG3 TAG4 12-Dec-2013 10:00 20 30 40 50 12-Dec-2013 10:01 30 10 20...
View ArticlePoll data at event based
I want to poll the data for group of tags at every 1 second in historian as per event based. If a batch is running then only collector shall poll the data for group of tags else it will stop polling...
View ArticleHistorical alarm
I am new in iFiX 5.0 user, and would like to run Historical alarm saving and displaying I have to write some tags from iFIX to PLC every 3 seconds I hope this WRITE TO PLC information not record to...
View ArticleiFIX 3.5 unable to start
My system was running fine. This morning after I restart my PC, when I want to run iFIX3.5 and I got the error message as "Warning, unable to open STARTUP.LOG. No startup history will be written to...
View ArticleAttribute names starting with @ or @@
Hi, In one of my project, I am seeing the extended attributes as below: @attribute1 @@attribute1 I am assuming that the attribute was used and deleted later or is there any specific meaning? So, the...
View Article32-bit float in just 1 register
We're using MBE 7 to communicate Modbus to an Eagle/Xartu. This RTU uses float variables (32-bits). Different from most equipments, Xartu puts all 4 bytes in just 1 register. It's ok to read it by...
View ArticlePAC 8000 Demo Sofware
Is there any possibility to Download a Program by Using PAC 8000 Demo software.As I have seen Download option is disabled.
View ArticleBackground Server as a service
Hi all & happy New Year! I'm currently converting an iFix project so that it runs as a Service. The background server also now runs as a service and what I've noticed is that some schedules that...
View ArticleWbcom.ini error
When I try to upload a HMI project from the quickpanel view unit, it connects and then gives me a choice of overwriting or a new project. Either selection will give me the following error. 'Wbcom.ini'...
View ArticleProblem installing PA 6.1.2
Hello All, I've a problem when I try to install Plant Applications 6.1.2 When starting the installation of plant applications server I get following error message: "This installation requires a valid...
View ArticleEMRP process crushes
The EMRP process crushes in about 5-10 minutes after project start. If restarted manually the process would still crash 5-10min later. The system is in service for several years and currently running...
View Articlealarms greyed out in summary ( redundant)
I have had some issues with the alarms being greyed out once I switch from primary to back up. Does anyone have an idea why ? Jim
View ArticleVersion 5.8 font size changing
If how create a new picture with three objects. object one is static text object two is a data link (dynamic text) object three is a pushbutton the pushbutton has a script to replace the picture now...
View Articlecomputer name
Does anyone know how to get the computers name in VB for iFix. NOT the node name but the computers name. Jim
View ArticleRunning SQL statements or VisiconX through WebSpace?
Is this possible?? I am trying to query the PDB using the Fix Real Time Data DSN and everything works fine on my SCADA1/dev box, but when I try to run the queries through webspace, nothing is...
View Articleaccessing element in array igs
I am trying to access a specific element within a static array in the igs driver (screen shot of driver config). the array f8_0 starts at zero and goes for a length of 59. The analog alarm block needs...
View ArticlePAC8000 Analog input Issue
I am using first time PAC 8000 8851 Controller SIL Certified.My First question is that is that controller Support Functional Block and Second I have an issue regarding Analog Input.Analog input is...
View Article