Problem with task priority in the Task List

I'm using task priorities to show the last started Task Steps on the top of others already running Tasks in the Mobile Task List (like Z-order in HMI systems). Whenever I've edited a workflow -...

View Article


Reset Versamax Micro

Dear, Is there any procedure to reset the parameters to default factory settings? I try to communicate with a IC200UDR140 ME 6.5 and is not possible. I place the PLC in STOP mode and 19200 baud, odd...

View Article


S/R coils

Hi, Do set/reset coils recognize transitions in PME? Or do I need to use a transition coil first? Thanks

View Article

iFix 5.8 MBE driver

I am disappointed that MBE driver needs license dongle to work in new iFix 5.8. We cannot check communication in demo mode while developing.:mad:

View Article

Are COM components like 'CimServer.tlb' compatible with 64 bit architecture?

Hi, We're trying to run an old VB6 application using Cimplicity COM components such as 'CimEdit.tlb', 'CimServer.tlb', 'CimVB.dll', etc. on a new Windows 2008 R2 (64 bit) server. We're running into an...

View Article


PDS and small floating point numbers

I am having an issue with the PDS driver in Cimplicity 8.2 SIM24. I have updated to PDS 3.6.9 without solving the problem. I am reading symbolic values from an Rx7i PLC. When a floating point number...

View Article

PLC to PLC data

Here is my challenge. We currently have 3 production lines with 7 Rx7iÂ’s on each line. At the front of each of the lines we have a genius module sending inputs to all 7 Rx7iÂ’s. We are in the beginning...

View Article

MBE Slave

Hi, I am trying to setup an MBE IGS driver to allow us to send data from our iFix server to IGS setup as Modbus Ethernet , which one of our clients Reads data from into their systems, also they need...

View Article


High Performance HMI

Does anyone know if GE has created any objects or Dynamo's for High Performance HMI? Things like Moving Analog Indicators? Thanks in advnace

View Article


IC200CPU001 Fault Problem

IC200CPU001+IC200PWR001 , The errors in the PLC fault are: Error Code: 198 ,Group: 135, Action: 3:Fatal , Task Num :3 Fault Extra Data: 00 02 84 28 00 00 01 f0 00 00 00 00 00 00 00 00 00 00 00 00 00...

View Article

WebSpace Autologin

Hello. How to configure autologin for iFix Webspace? It's possible?

View Article

Flipping object on condition

Is there an option that I can flip an object under a certain condition? Or it only can be done by using script?

View Article

TCPTASK.EXE error

I'm getting the following error in the IFIX event files... [TCPTASK.EXE] TCP/IP: All slots in set table used up [TCPTASK.EXE] assertion failed uiSktIndex!=PTHLIST_NULL file TCPLISN.c line 622 IFIX 3.5...

View Article


finding ifix version

Does anyone know if there is a way to look in a project folder(s) and determine what version of iFix it was created in ? Jim

View Article

iFix not up on terminal

Hi all! I am new on SCADA with TS. I am put online Microsoft RD. But not have success to run in the terminal. 1- I have installed iFix before activating Remote Desktop. Need reinstall iFix? 2- When i...

View Article


changing fill pattern programmatically

Is there a way to change the fill pattern and colours of an object using a script? I've searched through the help for the gefobject object model but can't find anything that might help. Any help...

View Article

Versamax addressing

I am new to the Versamax line, so please forgive me for this question. Does the Versamax not support symbolic addressing. This particular application is a Versamax 40. I looked at the the memory map...

View Article


Database redundancy in Cimplicity

Hi, I have two redundant Cipmlicity servers (8.2 SIM 24) and one viewer. I have done the following configuration regarding the DNS's and data logging: 1- At the Primary server: a) ODBC connection...

View Article

GlobalCare Survey, please help.

Hi all: I've been missing from this forum for a while now, but I hope you all will take a moment to fill out the survey which went out to globalCare members this morning. thanks -j....

View Article

only one dongle key seen at a time

I currently am running cimp hmi 8.0 sp12 on my machine and proficy machine edition 7.5, my problem is i i have both dongles in the computer but when i look at my license viewer it only shows the first...

View Article
Browsing all 2516 articles