PC Logic developer always running

Every since I installed PME 7.0 the PC logic developer is shown in my system tray. Is it actually running, I see no way to stop it or set it up to not start with Windows. I have no use for it as it's...

View Article


Scan Rate / Retry Count

Question: Does the Retry Count actually do anything? The reason is that I have a port that I configured for a 5 second scan with a retry count of 10. If the connection happens to go down just for one...

View Article


Proficy Machine Edition Control Question

We are currently migrating from PME 5.0 to PME 8.0 at the company I work for. Is there some method of setting up a work around so that the "Green Hand" releases control of the project after a set time...

View Article

Workspace startup opens *.fxg files

Hello! I am working on iFix3.5 installed on Windows 2000. When I start the workspace a bunch of userfxg files open in vb editor. I need to edit which fxg should be opened on workspace startup. I...

View Article

IC695ETM001 Modbus TCP client config

I am using IC695ETM001 as Modbus TCP client to read/write data to 8 devices with different IP addresses. I have used the COMMREQ commands, but i have noticed that I have to configure a delay of...

View Article


I/O driver for Yokogawa SLPC151

I need a I/O driver for iFIX ver 5.8 that can communicate with Yokogawa make Single loop controller SLPC151 model no. This has been communicating with FIX32 ver 5.5 on Windows98. Now the customer...

View Article

MBE and Multilin EPM

I have been trying to get the MBE driver configured to talk to a Multilin power monitor. Has anyone done this could offer some help? Thanks!!

View Article

Problems with webview

Have been having problems with incomplete web view screens when using IE11 on a 64 bit machine. Problem doesn't exist when browsed to by a 32 bit virtual machine. running IE 6 or another xp machine...

View Article


Error 1914 on Terminal Server

I have a terminal server running version 5.5. I have five scadas that I need to communicate with on this terminal server. The terminal server is communicating with four of these SCADAS just fine. Has...

View Article


Hist Tag Level Security - not working in RTIP

I have enabled Tag-Level security on a few tags in Historian. Historian tools (Admistrator, Excel) do seem to work properly--- i.e. viewing the tagnames themselves, and viewing data for those tags is...

View Article

Hist Tag Level Security - not respected in RTIP?

I have enabled Tag-Level security on a few tags in Historian. Historian tools (Admistrator, Excel) do seem to work properly--- i.e. viewing the tagnames themselves, and viewing data for those tags is...

View Article

iFix 4.0 w/Desktop Startup Picture Layout

I'm working on a customer's system that has several different SCADAs using the same set of pictures but different SCADAs are using different layouts (*.lyt) when starting view.exe. How do I determine...

View Article

Property Inspector Spreadsheet View on x64

There are several users that have been applying a workaround to re-enable the property inspector spreadsheet (column). Posted Workaround - http://forums.ge-ip.com/showthread.p...6855#post66855 Are you...

View Article


How to read faster then 100ms in OPC Driver?

Hello, i want to read my historical data in the historian 5.5 faster then 100msec, but in the OPC driver (ifix5.5) i cannot go faster then 100ms. Is there an other solution or do i have to change the...

View Article

iFIX 5.8 Terminal Server on Win 2008 32 bit?

E-books say Windows 2012 Server or Windows 2008 R2 is required. Is it really so, or is it possible to run the TS on Windows 2008 32bit (not "R2")? Microsoft TS CAL:s are installed and working. Regards...

View Article


Unknow mutex type

Hello, I am using Cimplicity 8.2 SIM 26.I have upgraded this from Cimplicity 6.0 I am facing the following error when I try to see trending of different configured points. Process:CV1fd4...

View Article

VisiconX to Proficy iHistorian

Hi I make queries of VisiconX to Proficy iHistorian. Timestamp format is in milliseconds. VisiconX v. 5.1.6815 example SELECT ihRawData. 'TimeStamp' as "Timestamp" ihRawData.Tagname as signal...

View Article


Failed to create object with alarm history viewer

Hello I have several Win7 Pro 64bit computers running Cimplity 8.2 with SIM 24. On some of them if I try to drop in the alarm history viewer object onto a screen I get the following error: "Failed to...

View Article

Modbus "C" Block Error Codes

Is there a document somewhere that lists the error codes for the RX3i Modbus "C" block available under developer downloads "DD152"? I have used this block a few times with serial port 2 on a...

View Article

How to configure Genius Blocks, besides a hand held device

Hi Forum, I have Rx3i PLCs with a "Genius Bus Controller" module talking to bunch of Genius blocks. I was told that, the only way to configure the Genius Blocks is thru a hand held module. Is there...

View Article