Changing point limits during runtime

Hi All, I want to allow a system manager to change the limits of a point via the project screens (rather than the Workbench dialogs). However I found that a point's limit properties (ALARM_HIGH,...

View Article


Quickpanel+ as a controller - Capability and Limitations

Hi, We are trying to convert a system with Versamax E05 with 400 I/O counts with Quickpanel+ & RSTi I/O. I need to know the max count of internal variables possible in QPV+. Is QPV+ memory is...

View Article


Rx 3i PLC not reading the analog input readings from particular rack

Im having rx3i redundant(ic695cpu310) plc with BEM331 GBC modules. Its been observed that irrespective of master ship of PLC(Rx 3i), the GBC -A is not reading only the analog data from serial bus...

View Article

Disk storage consumption with SIM 28

Hello. I just installed SIM 28 for Cimplicity 8.2 and I started to have a problem with disk consumption. After 2 days, there was no space left on C:/. 20GB in 2 days. I tried to find some file that...

View Article

Assign Dynamo Tag to User Variable

In Workspace Run mode, we want to be able to assign a selected dynamo tag assignment to a user variable at the selected dynamo click event. Our user variable is user.strTagName. The dynamo property...

View Article


Excel add-in for historian

I am trying to use the Excel add-in for iHistorian iFix 5.5 - iHistorian 4.5. The add-in is installed in office and checked but there is no tab for it. The only comment I found that made sense to my...

View Article

Auto Start Cimlayout with waitforproject

Hi everyone, I have a project with a CimLayout configuration. I want it to automatically start when I logon on Win7. I know there is a series of command line instructions for cimview to configure the...

View Article

Cimplicity 8.2 redundant system automatic changeover

Hi, We are using Cimplicity 8.2 redundant system and facing a problem. The system is automatically changing from primary server to secondary server and generating the following log Wed Oct 29 02:23:15...

View Article


Network OPC server

Dear all, We are using Cimplicity 8.2 SCADA system and facing a problem. When I am running an OPC server (OPC server for AC800M 5.0) in local node, corresponding Cimplicity device is up in Quick view....

View Article


Search for Historian tag by description

I need to animate an Historical chart pen. I will have the description property of the Historian tag needed. So if I know the Collector name and the tag description, how to I get the tag name to...

View Article

IGS not loading configuration file

I'm using IGS 7.58. Some times when I reboot the machine IGS fails to load the configuration. I have to manually select my configuration file. Has anyone seen this issue?

View Article

Multi-Field Tags & Array Tags

Has anyone successfully written to a Multifield or Array tag? We have tried everything and get nowhere. the command SetMultifieldValue comes up with "Type Mismatch" if we write to an array we get...

View Article

Fix32 to Proficy 8.5

Hi, I am trying to open an old HMI developed with Fix32. The project files backed up from site are a bunch of files inside folder "dynamics", an ".fbk" file, a "user.txt" file. I only have Proficy 8.5...

View Article


Fix32 to Proficy 8.5

Hi, I am trying to open an old HMI developed with Fix32. The project files backed up from site are a bunch of files inside folder "dynamics", an ".fbk" file, a "user.txt" file. I only have Proficy 8.5...

View Article

LM90 to Proficy ME 8.5

Hi, I am trying to open an old LM90 logic project (PLC90-70) in Proficy ME. The old project files are separated into several folders (program, SYSA, SYSB, and GMR). I think this is what they used to...

View Article


iFix 3.5 Esignature Issue

My customer has recently changed one of their lines from Local security to Domain security. The issue we are having is that if operators enter their login in lower case, the login fails. If they use...

View Article

Cimplicity 8.2 / 9.0

Support website seems to be a bit light on manuals for this stuff. Any ideas chaps ?

View Article


Cannot overwrite Project with Upload

I connected to a Versa Max with Proficy Machine Edition Logic Developer with the Laptop. The programs show logic not equal. I uploaded from controller to the laptop successfully but it still remains...

View Article

IFIX 4.0 w/Desktop Save PDB with Command Language Editor

Is it possible to save a PDB using the Command Language Editor? Run DBBsave? For example; I'd like to set up a screen that would modify database values, description, AA setpoints, etc. Then, I'd like...

View Article

How to read .IHA files on a different computer?

Hi Forum, in short: how to retrieve some .iha files from plant server to an office computer and read from it? We have a historian server (3.5) running in a plant, over the years, we accumulated lots...

View Article