Rx7i ic698bem731 gbc status
hi all I have Rx7i CPE030 PLC with ic698bem731 gbc , I did little logic with BUS_RD_WORD , but couldn't able to find the GBC status correctly http://support.ge-ip.com/support/res.../gfk0363ae.pdf this...
View Article.alm File Entry
There are a number of entries in the .alm file similar to the one below (with different tagnames) with no indication of source. Does this have something to do with the Historian (on a different...
View ArticleMBE driver comm failure alarm
Hi, I am using MBE as I/O driver in our system communication with PAC8000 hybrid PLC. I am facing an issue with communication break very frequently as its a wireless network. So I need to configure...
View ArticlePopup Screens NOT always on top in dual screen application
Hello. i connect 2 displays to the same PC and open cimplicity screens on both monitors, without any problem. the problem is when i open a popup display, a motor control, for example, on the MAIN...
View ArticleDynamically assign "Class" to "Person" ?
Is there any way to dynamically bind "Person" with "Class" ?
View ArticleProficy Historian server connection status in iFix 5.1
How to get the status of Historian server connection via TAGs in iFix 5.1? I mean if Client is not connected with Historian Server and if we are opening Historian Administrator from a Client PC, we...
View ArticleHistorian disables collecting of some tags after stop/start of cimplicity...
For some reason a few of my historian tags get disabled when I stop/start my cimplicity project. I have to manually enable for them to start collecting again. The tags are check marked in cimplicity...
View ArticleEgd
Can anyone let me know about any document covering the EGD configurations? I'm trying to add a "Remote IO Target (PAC System Rx3i)" in PME but I'm confused with the default Logic routines (password...
View ArticleIssue in importing variable to PME 7.0
Hi all, I'm trying to import the .csv file to PME 7.0 but unfortunately not successful till yet. The Variable import operation stucks and PME goes to no response. Can anyone let me know why it is...
View ArticleHistorian 3.5 A&E and SQL Server 2008 R2
Has anyone successfully used SQL Server 2008 R2 Standard with the Historian 3.5 A&E database? We are currently using SQL Server 2008 Express (not R2 Express) and have found a licensed copy of 2008...
View ArticleExcel Add-In (2010) Win2008 64bits
Hello, I've problems on working with a Winserver2008(Spanish), with a Historian 4.5 installed and Add-In Excel installed in a Excel2010 (Spanish). The problem is that I can add as a component but the...
View ArticlePME 7.50 - What's New
OK - PME 7.50 is on it's way to me! Just itching to try multiple cut and paste on FBD instructions and wires. Could it be this release? Ooooh the level of excitement could only be matched by the level...
View ArticleGenerate Report with Excel
Hi everyone, I was looking for an script that generates an Excel file with the data and points that I wanted. First, I used the forum "http://forums.ge-ip.com/showthread.php?t=12988" to generate a...
View ArticleMove Real
Gents I have a 90 70 PLC I have put a move real block in, when power flow goes to the block it should move a real variable from IN to Q This is not happening I ideas whats wrong? Cheers ijdk
View ArticleVersaPro Licence Transfer
Hello, Can anyone please help me overcome a problem I've created when transferring a VersaPro licence using a floppy ? This is the situation: We have an old laptop with a faulty screen. It has the...
View ArticleAutomatic User Logout
Having a problem where my users forget to manually logout of iFIX 5.5 and exceeding my lincense count of 9. This prevents other users from logging on. Tried using Login Timeout (8 hours) under...
View Articledumb question
I haven't tried it yet, but can I put a CMM321 ethernet in a 90-30 rack with a 364 or 374 cpu, and use the connection on 2 different subnets? (1 would be our plant network , the other would be local...
View ArticleUpgrade iFix 3.5 to ver 5.5
Hi, We have several systems running ifix 3.5 and there are data exchange among the system due to different location of data collection. Our client's direction is to migrate the OS to Windows 7 and...
View Article90_70
Could someone explain why in the ladder programme blocks, just below "main" there is a "called blocks" icon, in which some blocks are called, but not all, why do some blocks need to have a "call" and...
View ArticleRx7i Import/ Export Issues
Hi all, Do anyone know about some GE Document/Manual regarding Rx7i Variables import/ export guidelines or general issues occurring during import/export procedure. I'm stuck with importing a modified...
View Article