Hi All,
I am New User of Ge Fanuc PLC,I have some question which is confusing me.
1) Difference Between Proficy Machine Edition and Proficy Process System.???in which plc i can use PME and PPS??
2) what is PAC system,is Rx3i and Rx7i is PAC system or PLc Series.
kindly help.
:confused:
↧
January 14, 2015, 8:04 am
Does anyone have the help file for the Proficy Alarm Viewer?
↧
↧
January 14, 2015, 10:26 am
Is it possible to filter the Alarm Summary object to filter by status or value?
I don't see these available in the "Columns" options under the filter tab in the Alarm summary config dialog...
My main goal is to get rid of tags with a status of "NO DATA" or a value of "" (nothing)...
Any info helps!
↧
January 14, 2015, 10:57 am
Hello,
How can I know which animation a lookup table is for?
For instance a given object may have background, edge, fill and visibility as animations. However, the class name for all of them is Lookup.
I did use ListProperties but all of the properties for each animation look the same.
That would also bring up another question for Position, scale, rotate and fill- they seem to use class name Linear. How would I differentiate between which linear animation class belongs to what animation?
↧
January 14, 2015, 3:13 pm
iFix 5.5, we have Several AA & AI tags showing "RANGE" in the status column of the alarm summary. What does this mean & how can I suppress it?
↧
↧
January 14, 2015, 9:40 pm
Hi Everyone,
i want to upload program from from 90-30series ge fanuc.
Can Any tell me steps how to upload???
i am using PME .
:confused:
↧
January 15, 2015, 4:25 am
Does it possible to read from IED and just write the time on it using Modbus protocol (using function code 3 and 16 ) on the same channel or we can use 2 channel ? any adivce . Iam using Proficy Machine Edition 8.50
↧
January 15, 2015, 7:50 am
Hi.
I have a graphic object created in CimEdit. In runtime, I would like to dinamically change the position of this object following the values of an specific analog variable. Can this be done? Is there a command to draw an object on a specific location, giving it variables with the [X] and [Y] positions instead of fixed numerical values?
Thanks in advance.
↧
January 15, 2015, 6:35 pm
Does the #BatteryStatus register (used in the Quickpanel View HMI's) also exist in the Quickpanel+? We've been using this variable for years with the older HMI's, but now that we've upgraded to QuickPanel+ HMI's, it doesn't appear to be working correctly.
↧
↧
January 16, 2015, 5:45 am
Hello,
How can I know which animation a lookup table is for?
For instance a given object may have background, edge, fill and visibility as animations. The class name for all of them is Lookup.
I did use ListProperties but all of the properties for each animation look the same.
That would also bring up another question for Position, scale, rotate and fill- they seem to use class name Linear. How would I differentiate between these different animations for Linear types.
↧
January 16, 2015, 8:14 pm
Dear Sir,
We require Cimplicity Authorization code for one of our Development System which has crashed recently.
Serial Number:- 8604399736
System Key Code :- D798 7CE5 B4E5 8832 65
System Authorization code :- Required .
The previous details are as under :-
Serial Number:- 8604399736
System key code:- D614 889C B4C4 A94E 41
System Authorization Code :- FF1DFA354B181CE2E92E046A1A
I Request you to kindly provide the System Authorization code as soon as possible.
Thanks and Regards,
↧
January 16, 2015, 10:57 pm
I have following modules of series 90-30 PLC,
PART NO - CONFIGURATION MODE
IC693PWR321
IC693CPU341
IC693PCM301 - PCM CONFIG
IC693PCM301 - BASIC
IC693CMM311 - RTU/SNP
IC693BEM311
IC693MDR390
PLC application backups are available in LM90 software.
What is possibly to upgrade in VESAMAX series? What are equivalent modules? Is there any produce available?
What is possibility to upgrade in RX3i series? What are equivalent modules? Is there any produce available?
For IC693PCM301-PCM CONFIG and IC693PCM301-Basic module, as they are config with custom protocol, whats would be procedure to upgrade?
Thanks,
↧
January 18, 2015, 5:27 am
Hi everyone:)
Trying to poll data from Emerson Floboss S600+(Modbus Slave) by PAC8000(Modbus Master) by Modbus TCP, and display on Cimplicity 8.2
Need to poll data from Holding Registers (Cmd -3 [4xxxxx]) from Emerson Floboss S600+ For what concerns the floboss, after mapping of parameters in output register table, I`ve checked the data polling using Modbus TCP freeware application. Polling pass good, I can see all required data.
On PAC8000 side configured (by sequence):
1. Mapped data on "Map Remote Device Points from CPU"
- controller port - LAN using TCP
- Scan rate 100 (10ths of sec)
- Comm delay 2000
- Response timeout 2000ms
- Packing - Best Fit
- number of mapped points ~77 Floating point values
Now, using the "view live data" function i can see all configured values, trying simulate values from floboss - no reaction (with Modbus TCP app with disconnected PAC8000 - all works fine - data is refresh`s). Trying use Modbus TCP app with PAC8000 connected - error, means PAC8k using port...
http://s017.radikal.ru/i422/1501/5a/a48f439e3bd4.jpg
http://s017.radikal.ru/i414/1501/44/f011d0fbac47.jpg
http://s019.radikal.ru/i604/1501/fe/825467b14ffa.jpg
http://s50.radikal.ru/i127/1501/b4/b02ed3d0cc4d.jpg
Thank you a lot for ur replies
↧
↧
January 18, 2015, 9:30 pm
Hi All,
I am Using RX3i Pac series, i want to know,
how much Maximum I/Os i can use ??
:confused::confused:
↧
January 18, 2015, 11:27 pm
Hi all,
I am interested for feedback on the block count you have all experienced in programming PACS PLCs.
I have a number of RX7i/RX3i systems and all of them have more than 200 logic blocks in them. For a couple of the systems there is more than 400 logic blocks. The count is a consequence of a logic block for each drive std logic plus its sequence logic and just good organisation of the code into functional units and hierarchy (matches the HMI plant model structure).
The PACS has a limit of 512 logic blocks so I am starting to push up against this limit with possible plant expansions. The limit is hard to understand as there is heaps of memory available in the CPUs and the scan times are excellent (<20ms for logic solve and <50ms for sweep - mainly the redundancy sync time).
I have raised a product improvement request with GE a while back but it has no traction.
So I am interested in what others are seeing for large projects in a PACS environment. Any feedback most welcome.
↧
January 19, 2015, 6:14 am
Hi. I'm developing a .NET component for viewing Axis Network Cameras. Axis has an SDK to easily view the camera:
http://www.axis.com/techsup/cam_servers/dev/activex.htm. I created a C# control based off this SDK. When adding the control to a picture in Workspace there is an error "Failed to create component. See log for details." Log is below.
It looks like Workspace cannot find one of the SDK dlls. I tried to register the dll but it looks like it is not designed to be registered. Is there a folder I can put the needed dlls for this control that iFix can find them without the dll being registerd?
Code:
2015-01-19 07:56:20,274 [1] ERROR GEIP.Orion.DotNetComAdapters.DotNetComAdapter
Loading failed: C:\Data\AxisTestRelease\Occ1.AxisCameraControlLibrary.dll for AxisCameraControlLibrary.Occ.AxisCameraControl
2015-01-19 07:56:20,274 [1] ERROR GEIP.Orion.DotNetComAdapters.DotNetComAdapter
Exception has been thrown by the target of an invocation.
2015-01-19 07:56:20,274 [1] ERROR GEIP.Orion.DotNetComAdapters.DotNetComAdapter
Could not load file or assembly 'Interop.AXISMEDIACONTROLLib, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null' or one of its dependencies. The system cannot find the file specified.
--
Justin
↧
January 19, 2015, 6:22 am
Dear Friends,
I would like to know what is the easiest way to turn iFix into a Modbus Slave (RTU or TCP) i know i can do it using VBA but that option would be painfully hard,
any ideas?
Thanks in advance
↧
↧
January 19, 2015, 6:24 am
Dear all,
Iam using Modbus TCP to communicate between PLC and IEDs , i need to make Synchronization between IED and PLC so i need to read and write from and on the IED, the problem how could i manage read and write using the same connection (channel ) , when i tested the logic it reads only and if i forced read to off it can write only , how i could make the write and read operate together .
↧
January 19, 2015, 7:58 am
Good Morning,
I currently have a Quickpanel+ (part # IC755CSS15CDA) on a facility network. As it is currently set up, variables can be monitored from remote computers on the network but the HMI screens cannot be pulled up remotely. When I enter the IP of the HMI in an internet browser I noticed a Remote Viewer option but it asks me to download some software for my windows machine to be able to use Remote Viewer. However, after I download and install the software, it still asks me to install the software when I go to the Remote Viewer window. What do I need to do to set up the HMI so that the screens can be viewed remotely?
Thank you,
Bruce
↧
January 19, 2015, 8:22 am
Hi Everyone,
I'm using iFIX 5.8 along with Webspace for show a Historical Chart from an analog variable. On iFIX I'm using the object Chart_LineHist from Dynamo_sets for build the trend picture
I'm having problems of resizing the object when I call the picture, data is displayed fine but the main graphic area is moved out of the external frame of the object. (I wish I could attach a print screen, but I don't see how).
I look forward see someone else with the same problem or any advice.:confused:
regards,
↧