Overload on power supply
Hi all: This is about a PACSystem main controller rack. I have my power supply IC695PSA040 overloaded. 105.98% percent used the HW config is on a 12 slot rack and the modules installed are the power...
View ArticleHow can I make this transplant?
I have completed a project under the resolution of 1024X768, but now the new project should be run under the resolution of 1280X1024, but the old project seems some distortion, Can I make some changes...
View ArticleiFix 5.5: Problems with displaying System.CurrentTime
Hello, I have running a picture with a Dynamic Setting of System.CurrentDate + " " + System.CurrentTime Data Format "left", "Alpha-Numeric" and 22 Chars This display is running on 4 machines and it...
View Articlepoint cross reference help
I have a bunch of signals on various screens that are undefined. Is there anyway to search and list all the undefined signals in a project ? Jim
View ArticleIncorrect Alarm Area Totals
I'm using the alarm area total (fix32.scada.area.A_AREA_TOT) to visually display on a map when a piece of equipment is in alarm. Currently one of my alarm area totals is showing a value of 26 alarms....
View Articlealarmcast error
Followed all pdf instructions. Have gate way on the cimpliciy pc and alarm admins on a different pc. The alarm gateway is sending the alarms to to the alarm cast server according to the alarm cast...
View ArticleCimplicity Freeze
We are experiencing application crash issues on an older Cimplicity 6.10 system. The system is scheduled for upgrade in conjunction with another project but needs to continue to run in the mean time....
View ArticleCimplicity file load error
Hi all, We are old school here and using Cimplicity 4.01. on a machine. There are currently a couple thousand recipes on the machine that can be called up and loaded. It seems certain recipes when...
View ArticleTrendX flatlines
Hello, I'm using ME Proficy View 7.5 with an HMI to monitor 25 different temperatures, all the temperatures are being logged and I can view them in the program TrendX but sometimes TrendX shows a flat...
View ArticleiFix 5.5 MMP Driver Problem
I am upgrading from a Fix 32 node to a iFix 5.5 system on a Windows 7 PC. I am having trouble with getting the MMP driver to work in iFix 5.5. When I click configure it will not work. Has anyone else...
View Articlecall '/Keypad ' from the screens
I am trying to use the Cimplicity Built-in /keypad function. Is there a way to call this keypad through instead of command line argument. As we have lot of Viewers deployed already, and I want to...
View ArticleConfig NE
I have a Rx7i CRE030 (redundant) and one of the CPUs comes up with: ---------- Verifying ---------- ---------- Hardware Configuration ---------- MASTER HARDWARE CHECKSUM NOT EQUAL...
View ArticleModify Current Time and Date
Hi! I just have a silly question this time! I have made a small Scripting that changes the current Time and Date. Code: Private Sub CommandButton1_Click() Dim password As String Dim new_date As String...
View ArticleAdding comments to a Workflow
Is it possible to add text/comments/documentation to a workflow? I would like to add comments to Workflows that describe what is happening in laymen's terms. What is the best practice for documenting...
View ArticleHow GECssOPCServer can serve data from different HMIs ?
I am an IT person and I need to understand the server diagram. This post may sound vague but please feel free to correct me. We have three GE HMIs. Earlier we had three opc servers on each of them....
View Articlecimplicity system alarms display
How to hide system alarms from Alarm banner . for example : when DB connection is not done , it shows "Connection no DB is lost". I wants to hide this kind of system alarms from Alarms banner.
View ArticleVersamax IO card status on RX3i PLC
Hi, I'm using RX3i IC695CPE305 CPU and connected to versamax modules IC200MDL740,750 and 650 connected to iFIX SCADA system via ethernet. I would like to have the CPU status, Powersupply card status,...
View ArticleProblems with user in Globalview
Hi, I have a problem with one user to log in Globalview. We have installed Cimplicity 8.2 with SIM 19, and we have 5 licenses of Globalview. To allow people to log in, IT department has configured one...
View ArticleHow to force a WriteValue to act immediately?
Hi, In one of my Fixbackgroundserver VBA script, I use a WriteValue routine to reset a DI stored in SIM2 and then I launch another function which test the value of this DI. My problem is that...
View ArticleMaintaining manual numeric inputs after system crash
Hi, I have developed a screen to manually input water sample results. The problem is, if the system crashes, all the values return to 0 on start up. Is there a way to retain the last value input?
View Article