SQD & SQT versus VBA ADO
I am a relative newbie so please don't shoot me down if this has already been asked. I have gathering energy usage data over the network via modbusTCP. At the moment, I have 6 meters to read, but will...
View ArticleTHISNODE and Webserver
I will be using iFix5.5 on node1, and webserver on node2. If I enable THISNODE on node 1, this will give me the flexibility to produce pictures for a node3 which will be identical to node1, thereby...
View ArticleTags Not Showing Up In Historical Selection
I am using iFix 5.5 on a Windows 7 32-bit. I have the tags configured in the historical collection, I look in Mission and see the HTC running. It is in the tasks when started and set to background. I...
View ArticleHow to delete "Groups"
It is easy to create an group in "Security Groups", but encountered error messsage when attempt to delete it: Failed to delete Group - The object is currently in use. PS: WORKFLOW version 1.5 SP2 Only...
View ArticleUrgent: Block on SCAN AI
Hello, I am setting my alarm limits (.A_LOLO, .A_LO, A_HI, A_HIHI) of my AI tags (SIM driver) with VBA in picture. When I do that alarm is still in database even if it is not an alarm anymore. And...
View Article2.0/6.1.1 - Silverlight DataCell - Limits
I just created a test form using the Silverlight DataCell component in a Workflow form. I attached a cell to a variable that had limits defined, but no limits were shown in the context menu. Has...
View ArticleRegister time issue with Current Year
I guess we are in 2013 where as register form only accepts "2012"!!! A guessing and try worked! please update the same :)
View ArticleSockets and Cimplicity 8.2
Hello everyone, I got a task to connect to a few peripheral devices using TCP/IP. To be consistent with all other HMIs (Cimplicity 8.2) and because the interface with these peripherals will require...
View ArticleHow to config project startup...
I have a project ("D:\Scada") To open, i do: - Run Ifix, then - Run Workspace Now I want have shortcut (same the shortcut to open Sample Ifix on desktop) to do: - Run Ifix - Run Login (if Ok then Run...
View Articleprogramming CPU by proficy machine edition
I have changed type 364 pcu to 374 and i have problem installing the new program. I am using proficy machine edition. The 374 cpu is new. I have error codes on the proficy machine edition and cannot...
View Article'Bad' Tag Causes Reader Service Delays
Had an issue where some equipment was taken offline for maintenance. We have tags in Plant Apps(PA) to calculate the average with a sampling window of 1 minute. We are running PA 5.0 and there was a...
View ArticleExcessive Time to Build Changes
I'm currently doing some PLC code development for a project using Proficy Machine Addition V7.0 SIM 7. We're using the RX3i range of PLCs with a IC695CPU320 processor. Whenever I build any code...
View ArticleLM90 to Proficy ME Conversion
I have a 90-70 program in LM90. This particular PLC has an interface to several DC300 drives using GE's DLAN card (IC697BEM763). I was able to import the program without any major issues, just a...
View Articlechanging IP address of quickpanel control
I have tried to change the address of quick panel control as described in the manual. It accepts the change but when i ping it from my PC , i get no reply. But when i change back to the old IP address...
View Articlequickpanel control memory
When i try to run view runtime on qp control i get the message program memory low. I bought a 2 gb flash card. The program memory when viewed in memory set up is now 15 mb but i still get memory low...
View Articlehow to create navigation bar and CIMLayout in cimplicity 8.2
Hi all, I have cimplicity 8.2 installed on windows 7. I have a very simple question that how to create navigation bar and CIMLAYOUT file in cimplicity 8.2 projectless version. I already have some .CIM...
View Article[Question] Dynamo Set
Hi guys, I just wanna create a dynamo object, which is working like: - Showing form to assign data tags to animation object - Create event click, which is calling to other form to working in runtime...
View ArticleToolbox ST version 04.04 Trip log problem
Hi all, I am facing a problem with Triplog in controlST. Actually the data which it is logging and retaining is only for the last 3 days. However, my requirement is that i want trip log to retain data...
View ArticleDebug message from iFix: Fault tolerant heap shim applied to current process
When I run our customer OPC driver, I see this strange message in DebugView which, when I google has zero results. It's a very strange message: [4776] FTH: (4776): *** Fault tolerant heap shim applied...
View Article