CPE310 EGD configurartion
Hardware configuration CPE310 Rx3i CPU with EBI001 VersaMax ethernet NIU. I am trying to configure the EGD but for Adapter Name it is showing error in ConsExch1 and ProdExch1 even i put it 0.1 which...
View ArticlePAC8000 communication with 90-70 PLC
Hiii, I have 2 diffetret system: GE 90-70 GMR dule redundunt system with IC697CMP790 - CPU & IC697CMM742 ETHERNET TCPIP MODULE and PAC8000 PLC. what is the best possible way to communicate this 2...
View ArticleDowntime Report
Perchance, does anyone have an Excel file using the Add-in that they could please share with me? I now have data and the Add-In is great however I am struggling. I am not asking for someone to create...
View ArticlePoint Referencing (for Proficy View)
I'm sure this may have been posted before, but I can not seem to find it. I am currently using the toolchest for linked objects where I create a graphic that inherits a Data Type Structure from used...
View ArticleGetting "System Error &H80040111 (...) in iFix 5.5
Hi all, I get the "Mircosoft Visual Basic" message System Error &H8004011 (.2147221231) within the visual basic code, when I try to execute normal VBA functions like Ucase(), strLen() within the...
View ArticleDMDDE start up
We are using ifix 3.5 and I have a spreadsheet I am using to publish some data I am gathering off of a couple SCADA nodes. Every data change is causing a memory increase in excel and I am able to...
View ArticleHow to upload PCM301 Module Configuration
I have GE Fanuc CPU341 application program in Logic Master 90. When open I/O configuration of IC693PCM301 modbule it shows Config Mode - PCM CFG. I want know how to upload configuration PCM301 module,...
View ArticleLockScadaSYNC Timeout at the Enhanced Failover (iFix 5.8)
I have a problem whith the Enhanced Failover (iFix 5.8). At the DebugLog in ScadaSyncMonitor (Secundary) I receive many: LockScadaSYNC Timeout PDB Sync - RestorePDB LockScadaPDB timed out Any...
View ArticleiHistorian Add-in and OpenOffice
Is it possible to use the iHistorian Add-in with OpenOffice products? Thanks,
View ArticleSend mail through Outlook using BCE
Hi, I need to send mail through outlook which is configured in the SCADA PC using BCE. I tried below code, but getting error on second line. Set objOutlook = CreateObject("Outlook. Application") Set...
View ArticleTrying to connect to PLC via TCP/IP
We have a vacuum pressure test machine(the PLC), Sentinel I-28 is the name. My options on the machine itself are serial and telnet connections. I have a PC with iFix 5.8 installed. The PLC sends the...
View Articlewhich driver to use for reading %W addresses from PacRx3i to ifix?
I have a big question, which driver i must use to get data in iFix from %W addresses (pacRx3i), because GE-SRTP driver is not supported on Windows 7? Best Regards
View ArticleWill IGS version 7.514 work with ControlLogix Version 24?
AB Studio 5000 version 24 has been released with V24 firmware. Is anyone using this with IGS and does it work? We are using some Version 23 firmware and they are working fine.
View ArticlePCOP Software
I need PCOP software. I check with GE authorized supplier in UAE, it is not available with them. From where can I get this software.
View ArticleONe pic out of 3 rolled off botton after 5.8 update
I have a menu bar across the bottom of a screen that in v5.5 worked fine. Upgraded to 5.8 and this menu bar has now slid down so that I can only see the very top of it. I expected some changes with...
View Articlewill 5.5 client read 4.5
Using new v5.8 iFix clients, intending to read from iHistorian v4.5 (for now) ... will the iHistorian client from the 5.8 Cd work to read the v4.5 machine? I believe I have to install that toolbar and...
View ArticleUSB to Serial Adapter
I am running iFix5.5 as a client and using Modbus. When I run MBE Powertool and try to connect, I get a Connection Not Established message and then prompts me for a different server. Could it be the...
View ArticleUSB to Serial Adapter
I am running iFix5.5 as a client and using Modbus. When I run MBE Powertool and try to connect, I get a Connection Not Established message and then prompts me for a different server. Could it be the...
View ArticleLooking for an NVIDIA Tegra System On Modules
NVIDIA Tegra System On Modules which comes with latest Tegra version, minimum 2GB RAM, Quad Core and should support both Windows and Linux Operation Systems. Any suggestions?? Sorry I don't know...
View ArticleLogic master
Hi All, I am New user of Ge Fanuc PLC,some body please help. i Have Ge fanuc series 5 PLC(Ic655) old plc,I want to upload Program from it after that download in another 90-30 series PLC. Some Body...
View Article