In iFix Database Manager can you sort by Enable Alarming?
I just want to see the blocks that have an alarm set. The only column I can find “Alarm Enabled?” Shows ‘NO’ for every block. Whether the Enable Alarming check on the blocks Alarms tab box is checked...
View ArticleColor of Ref. address
To exchange an address number between variables, I found that only 2 of letter(Ref Address) is yellow color in Inspector window. In Navigator of Variables, Ref Address is yellow(%AQ0701) Is there some...
View ArticleConnecting Ihistorian database with OLEDB provider in .Net
Hi Folks, I am trying to connect to Historian Database from my C# .Net Application using an oledb provider. But i am getting the below error message . 'ihOLEDB.iHistorian.1' provider is not registerd...
View ArticleOne Picture for 50 controls - How make button variable?
Hello, i want to make one picture variable with TGD-files. This works fine for the animations, but how can i do a variable toggledigitalpoint in the scripting behind the button. I want to read the...
View ArticleFixEvent trigger on page open
Hi All, I have a picure with 11 FixEvent using this configuration: ErrorMode = 1 EventType = OnDataChange Interval = 01.00.00 IsSelectable = False QueueEvents = False Source = a signal value Each...
View ArticleCould not Resolve DLL Function Address and Other Error messages
For some reason iFIX 5.0 won't start up on Windows 7 . I just get an error saying "Could not Resolve DLL Function Address". Not the most helpful or informative error message I've received. Does anyone...
View ArticleFix32 on a virtual machine
I'm trying to get an NT4 virtual machine up and running with Fix32 V6.12, but it will not start correctly. The startup log is: Executing task: NNTABLE.EXE Loading module: NSD.DLL Can not load module:...
View ArticleSwitching of IP address in MBE using iFIX
Hi all, I have two modbus devices with an IP each. Both the devices are connected to a ethernet switch and then connected to iFIX SCADA. In MBE, both the devices are configured in a single device ie,...
View ArticleWsactask.exe crash all days at 5:00am Ifix 5.5
In a new Upgrade Scada, have this problem whit Ifix 5.5 (Windows 7). 3 times rebuild all, and the same All days at 5:00am the data in the Scada, not continúe working, and need to restart the Scada....
View ArticleAlarm Acknowledgement
Hi people, I am hoping someone can help me here as it is driving me crazy. I have an application with current alarms screen that shows when an alarm is present. This used to work but now the alarms...
View ArticleAlarm Viewer ACK timestamp
Hi everyone, I have an Alarm Viewer that shows me the Current Alarms with the timestamp of the alarm, message, comment and if it's acknowledge or not. My doubt is: how can I show the timestamp of the...
View Articleprevent TRIGGER SMART OBJECT
Does anyone know how to prevent a user from Triggering a smart object when the right click on the object ? Jim
View ArticleWincfg v2.0
Can someone help about wincfg v2.0 for Data panel H old program to open? Thanks in advance.
View ArticleBlinking green on light on RX3I processor
I have been using the processor, back plane, 004 com module, and power supply for about 45 days with no problems. I downloaded a converted 90 30 program into the processor and installed it into the...
View ArticleTX substring as DataSource caption
Hi all, I need to create a DataLink showing only a substring of a TX signal. (eg. I have a 8 chars TX signal and i need to show only 5 chars starting from the second). Is there any simple way to do...
View ArticleSQL Linked Server to Historian 5 (weird tag behavior)
We basically followed the instruction in the e-book to setup a SQL Linked Server to Historian 5 and it's working. But we're getting some weird data when performing SQL calls. We're using Quickpanel...
View ArticleMigrate an 3.5 Ifix application to Ifix 5.5
Hello, I have a couple of 3.5 Ifix applications that I need to convert to Ifix 5.5. Up 'till now, the only way I found effective is to install Ifix 3.5 on a VM, restore the application, then install...
View ArticleCIMPLICITY OPC to RX3i
Is it beneficial to utilize multiple OPC connections ( Master_OPC_1, Master_OPC_2, etc ) to communicate to 30+ PLC, OR, only use 1 connection - Master_OPC_1.
View ArticleUsing Multiple OPC Connections in CIMPLICITY
Is it beneficial to utilize multiple OPC connections ( Master_OPC_1, Master_OPC_2, etc ) to communicate to 30+ PLC, OR, only use 1 connection - Master_OPC_1.
View ArticleVersamax Serial to Siemens MP270 HMI
I'm using a Versamax to talk over serial communication read/write to a Siemens MP270 HMI. If I power down the system then power back up, The PLC comm port stops communicating. Also if I stop the HMI...
View Article