set point to empty value

Cimplicity 8.2 CIM 14. Windows 7 64 bits I have a point Area.Unit.Name with String_20 datatype. How can I set to to empty value in VB script ? PointSet "Area.Unit.Name", "" returns Bad Conversion for...

View Article


Workflow Issues: Why some workflow Instances are not visible in Task List

I have been working on workflow version 1.5 and now version 2.0. I have seen an issue wherein one my Workflow triggered from another workflow is not visible in task list (it was visible before) while...

View Article


Profibus PA Analogue Values

Hi, I am reading values from an E+H Cerabar Transmitter, Status and 4 Byte Float, on a 90/30 using a PBM200, does anyone know of a neat way of converting the Float to a readable format? Big Endian...

View Article

Cimplicity 7.1

GE FANUC PLC : VERSAPRO. ; IP address : 3.0.0.1 HMI/SCADA : CIMPLICITY 7.0. ; IP address: 3.0.0.15 Communication :Ethernet. PLC is running mode. Data is updatng in PLC program but not showing in HMI....

View Article

Proficy Historian Server 4.5 Setup

Hi all, Can anyone please tell me that whether the installation CD of cimplicity 8.2 contain all these tools 1) Proficy Historian Server 2) Historian Client tools 3) Historian Collectors 4) Historian...

View Article


Alarm migration Tool fails to complete

Anyone have experience migrating their old AE Database to the new structure in Historian v5.0 using the new Proficy Alarm Migration tool. It seems to fail to complete if it has any issues. The...

View Article

Java update

Hello, can you always update the Java on the RTIP? Does the clienst then keep working? Or do they also need an update? Grtz. Speedy

View Article

Cimplicity 8.2 DVD contain historian or not?

Hi all, I have a very simple question that i have already installed cimplicity 8.2 on windows 7. Now i want to work on proficy historian 4.5. I want to know that whether the historian built-in the...

View Article


cimplicity server, viewer issue

i have a cimplicity server redundant 35000 points systems with 4 viewer unlimited points system. i didnt share any folder from server to viewer instead of that i just copied all the screens and paste...

View Article


Finding the oldest "still up" alarm only using Database ?

Hi everyone, I'll be using iFix SCADA as a "PreProcessor" between a plant and Proficy PlantApps (above other things). To synthetize the inputs, the production line has about 300 alarms (let's call...

View Article

Environment Security Not Working

If I enable Environment Security, I loose Windows task bar, but I can still perform task switching (ALT and TAB key), even when I'm logged in as a guest (which should not be able to do this). System...

View Article

Warning popup

Hello, In iFix, Is there any warning popup such as message box that can ask you if you are sure to to the action?? I want to give this to a pump start stop push button. The operator should be asked if...

View Article

DO tags initially unknown

Hi,, I am facing a difficulty while using DO tags. As I import it to the database manager, it is shoeing as ???? value even if the communication is healthy. But as I force from database manager as...

View Article


Result Set for Managing Var Specs

I would like to create and approve a transaction for variable specifications so this can be done outside of the PA Client. I can only find functionality in the SDK and cannot find a result set to use....

View Article

iFix 5.5 alarms

Hello, I have several AI tags in PDB wich are in alarm state, they are on scan but I do not see them in AlarmSummary window. Alarm filter is not an issue. If I put tag off and on scan then I see it in...

View Article


Scheduler DataChange condition triggered when I swith to Run Mode ?

Hi, I'm trying to design a scheduler to follow the evolution of a machine running state and do some actions when the machine goes ON or OFF. Thus, I created a "OnChange" event on the RUNNING tag...

View Article

BQM_ALR Creating A Logfile

We have a logfile that is continuing to grow on our Cimplicity 7.5 system that is currently at 1GB in size (and growing). The file is in the temp folder and is named LogFile_<Project_Name>A...

View Article


Redundant Server OPC Collector

Hello, We have 2 servers, the main one and the secondary. We have a redundant system. The main one have installed a OPC Collector that collects tags from Cimplicity to another node that has Historian....

View Article

RX3i Dual Bus Genius Redundant Controller

I submitted an inquiry via Technical Support Service Request, the Senior Support Professional who handled my question suggested I use this form to continue my inquiry. A customer is running redundant...

View Article

Is it possible to use IC660BSM120 in redundant serial networks?

Is it possible to use a Bus Switch Module IC660BSM120 in a redundant serial network? I saw an app that use 2 PCM 90-30 coprocessors to read power values from some Multilins in a rs485 network. This...

View Article